Measuring Tools · Marine Portable Water Test Kits

TEST KIT WATER MARINE PORTABLE 652825

Portable drinking-water test kit for ships: the ten parameters one flag requires a self-test kit to determine, test intervals, records and refills.

What it is

IMPA 652825 is a portable kit the crew uses to test drinking water on board. The code name gives no list of contents, so two suppliers can quote very different kits against the same code.

The kit is how a ship tests its own water between laboratory checks. Some flags allow self-testing in place of sending samples to a laboratory, but only if the kit covers set parameters.[1]

How to specify and order it

Write the parameters into the requisition. Portugal’s Circular No 74 lists what a self-test kit must clearly determine: coliforms and E. coli, intestinal enterococci, total bacteria count, Legionella, copper, chlorine and pH, turbidity, colour, iron and conductivity. That list is a useful benchmark even if your flag is not Portugal. A chlorine-and-pH kit alone covers only one line of it.[1]

Ask the supplier how the kit performs the bacteriological tests, how long a result takes and how many tests the reagents give. Ask too for the refill part numbers so reagents can be reordered without buying a new kit.[1]

If the ship doses Hadex (550665 to 550668), the maker offers Waterlab test kits that measure the amount of active Hadex in the water. State whether the kit must read that, or free chlorine generally.[2]

Rules and approvals

Under the Portuguese circular, tanked drinking water must be tested at least once a year. The sample is drawn at the final dispensing point after it has flowed through the system. A ship that self-tests must do so every six months. If a result exceeds the WHO Guide to Ship Sanitation, use of the water is suspended and sealed samples go to an accredited laboratory. The master keeps test records for port State and flag inspectors.[1]

Questions buyers ask

What should a ship’s drinking-water test kit measure?
One flag’s list for self-testing: coliforms and E. coli, intestinal enterococci, total bacteria count, Legionella, copper, chlorine and pH, turbidity, colour, iron and conductivity.
How often must drinking water be tested on board?
It depends on the flag. Portugal requires at least yearly testing of tanked water, and six-monthly testing when the crew use a kit instead of a laboratory.

Published by Sherif Awad, founder of GeoMarineHub — in ship supply since 1990, a family business since 1981 (45 years). Last checked .

Requests by e-mail · no account needed

E-mail the requisition for IMPA 652825

No account needed. Send the code, the quantity and the port of call — or the whole requisition as it left your desk — and verified suppliers at the port price it, sealed, on the same thread.

supply@geomarinehub.com
  1. 01

    Send

    Excel, PDF or typed into the mail — whatever your system produced.

  2. 02

    Receipt

    Within minutes, naming what we read and anything we could not.

  3. 03

    Offers

    Priced by verified suppliers at the port, back on the same thread.

Most requested sections